Audiowell logo Slideshow Image Script

ULTRASONIC FLOW TRANSDUCER/SENSORS

US0014-001
Ultrasonic Flow Transducer/Sensor

Model T/R975-US0014L353-1 The transducer is the core element of the ultrasonic flow meters and level sensors. Audiowell transducers use the transit time principal where opposite sending and receiving ultrasonic flow sensors are used to transmit signals through the flow. The signal travels faster when moving with the flow stream than against the flow stream. The difference between the two transit times is used to calculate the flow rate. The Audiowell flow sensor is normally accurate to less than 1% for the flow rate. Designed with a rugged metal case, this transducer can be mounted with direct contact to the liquid. The robust design allows for the transducer to be resistant to water pressure affecting performance while decreasing any distortion caused by environmental factors. It's unit block construction makes for easy mounting and to solder. The lower power consumption allows for battery-operated applications.

Applications:
For Flow meters, level sensors, under water level meter or sensor. An excellent device for water heating systems and pump applications.

Dimensions:

US0014-001 dimensions

Specifications:

No. Item Specification
1 Resonant Impedance ≤ 110Ω
2 Resonant Frequency 975 ∓ 30KHz
3 Static Capacitance 1150 ∓ 20% pF
4 Pressure Resistant 2.5Mpa



US0012-000
Piezo Transducer for Flow and Level Sensors

Model T/R975-US0012L391-01 The transducer is the core element of the ultrasonic flow meters and level sensors. Designed with a rugged metal case, this transducer can be mounted with direct contact to the liquid. The robust design allows for the transducer to be resistant to water pressure affecting performance while decreasing any distortion caused by environmental factors. Its unit block construction makes for easy mounting and to solder. The low power consumption allows for battery-operated applications.

Applications:
For Flow meters, level sensors, under water level meter or sensor. An excellent device for water heating systems and pump applications.

Dimensions:

us0012-000 dimensions

Specifications:

No. Item Specification
1 Resonant Impedance ≤110Ω
2 Resonant Frequency 975 ∓ 30 KHz
3 Static Capacitance 1150 ∓ 20% pF
4 Pressure Resistant 4.0Mpa



US0002-000
Ultrasonic Flow Transducer/Sensor

Model T/R975-US0002L340-1The transducer is the core element of the ultrasonic flow meters and level sensors. Audiowell transducers use the transit time principal where opposite sending and receiving ultrasonic flow sensors are used to transmit signals through the flow. The signal travels faster when moving with the flow stream than against the flow stream. The difference between the two transit times is used to calculate the flow rate. The Audiowell flow sensor is normally accurate to less than 1% for the flow rate. Designed with a rugged metal case, this transducer can be mounted with direct contact to the liquid. The robust design allows for the transducer to be resistant to water pressure affecting performance while decreasing any distortion caused by environmental factors. It's unit block construction makes for easy mounting and to solder. The lower power consumption allows for battery-operated applications.

Applications:
For Flow meters, level sensors, under water level meter or sensor. An excellent device for water heating systems and pump applications.

Dimensions:

US0002-000 dimensions

Specifications:

No. Item Specification
1 Resonant Impedance ≤ 110Ω
2 Resonant Frequency 975 ∓ 30KHz
3 Static Capacitance 1350 ∓ 20% pF
4 Pressure Resistant 1.6Mpa
5 Storage Temperature -25℃~+55℃
6 Operating Temperature +4℃~ +90℃
7 Operating Voltage ≤5Vp-p



US0005-000
Ultrasonic Flow Transducer/Sensor

US0005-000The transducer is the core element of the ultrasonic flow meters and level sensors. Audiowell transducers use the transit time principal where opposite sending and receiving ultrasonic flow sensors are used to transmit signals through the flow. The signal travels faster when moving with the flow stream than against the flow stream. The difference between the two transit times is used to calculate the flow rate. The Audiowell flow sensor is normally accurate to less than 1% for the flow rate.
Designed with a rugged metal case, this transducer can be mounted with direct contact to the liquid. The robust design allows for the transducer to be resistant to water pressure affecting performance while decreasing any distortion caused by environmental factors. It's unit block construction makes for easy mounting and to solder. The lower power consumption allows for battery-operated applications.

Applications:

For Flow meters, level sensors, under water level meter or sensor. An excellent device for water heating systems and pump applications.

Dimensions:

US0002-000 dimensions

Specifications:

No. Item Specification
1 Resonant Impedance ≤ 110Ω
2 Resonant Frequency 975 ∓ 30KHz
3 Static Capacitance 1350 ∓ 20% pF
4 Pressure Resistant 1.6Mpa
5 Storage Temperature -25℃~+55℃
6 Operating Temperature +4℃~ +90℃
7 Operating Voltage ≤5Vp-p